Jumper Block Settings Intel
®
Server Board S5000PAL / S5000XAL TPS
Revision 1.7
Intel order number: D31979-010
60
6. Jumper Block Settings
The server board has several 2-pin and 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server board. Pin 1 on each jumper block is denoted by an “*” or “”.
6.1 Recovery Jumper Blocks
Table 32. Recovery Jumpers (J1D1, J1D2, J1D3)
Jumper Name Pins What happens at system reset…
1-2
BMC Firmware Force Update Mode – Disabled (Default)
J1D1: BMC Force
Update
2-3 BMC Firmware Force Update Mode – Enabled
1-2
These pins should have a jumper in place for normal system operation. (Default)
J1D2: Password
Clear
2-3 If these pins are jumpered, administrator and user passwords will be cleared
immediately. These pins should not be jumpered for normal operation.
1-2
These pins should have a jumper in place for normal system operation. (Default)
J1D3: CMOS
Clear
2-3
If these pins are jumpered, the CMOS settings will be cleared immediately. These pins
should not be jumpered for normal operation
TP02080
3
2
Password
Reset
J1D2
J1D3
3
2
Clear
CMOS
BMC Force
Update Mode
3
2
J1D1
Disable
Enable
Figure 17. Recovery Jumper Blocks (J1D1, J1D2, J1D3)